Industrial facilities that handle combustible gases and vapours need reliable monitoring systems to identify potentially dangerous gas concentrations before they reach hazardous levels. Whether in manufacturing plants, chemical processing facilities, energy installations or storage areas, continuous gas monitoring is an important part of industrial safety management.

One established technology used for detecting flammable gases is catalytic gas detection. This technology is widely applied in fixed gas detection systems where continuous monitoring and integration with industrial control equipment are required.

In this article, we explain how catalytic gas detection works, what factors influence its performance, and what to consider when selecting a fixed gas transmitter for industrial applications. We also take a closer look at the GfG CC33 fixed gas transmitter, designed for monitoring combustible gases and vapours.

1. What Is Catalytic Gas Detection?

Catalytic gas detection is a measurement technology used to detect combustible gases and vapours in the surrounding atmosphere.

The technology is based on catalytic oxidation. When combustible gas comes into contact with a heated catalytic sensing element, an oxidation reaction takes place. This reaction generates heat, causing a measurable change in the electrical resistance of the sensor element.

The resulting electrical signal is processed and converted into a measurement value representing the gas concentration.

Catalytic sensors are commonly used to detect gases such as:

  • Methane (CH₄)

  • Propane (C₃H₈)

  • Butane (C₄H₁₀)

  • Hydrogen (H₂)

  • Ethylene (C₂H₄)

  • Ethanol and other combustible vapours

The exact gases that can be detected depend on the selected sensor and its calibration.

2. How Does a Catalytic Gas Sensor Work?

A typical catalytic sensor contains two elements: an active sensing element and a reference element.

The active element is coated with a catalytic material that promotes the oxidation of combustible gases. The reference element provides a comparison and helps compensate for changes in environmental conditions.

When combustible gas reaches the active element, oxidation generates heat. This changes the resistance of the sensing element. The electronic circuit measures the difference between the active and reference elements and calculates the gas concentration.

The measurement is commonly expressed as a percentage of the Lower Explosive Limit (%LEL).

What Does %LEL Mean?

The Lower Explosive Limit (LEL) is the lowest concentration of a combustible gas in air at which ignition can occur.

For example, a reading of 20% LEL means that the measured concentration is equivalent to 20% of the gas's lower explosive limit.

It is important to understand that %LEL is not the same as gas concentration expressed as a percentage by volume. The relationship between these values depends on the particular gas.

Monitoring gas concentrations relative to the LEL allows industrial safety systems to identify increasing combustible gas levels and initiate appropriate warning or control actions.

3. Catalytic vs. Infrared Gas Detection: What Is the Difference?

Catalytic and infrared (IR) technologies are both used in fixed gas detection systems, but they operate according to different physical principles.

Understanding their differences is important when selecting equipment for a particular industrial application.

Feature Catalytic sensor Infrared sensor
Measuring principle Catalytic oxidation Infrared light absorption
Main applications Combustible gases and vapours Specific infrared-absorbing gases
Oxygen dependency Requires sufficient oxygen for catalytic oxidation Does not require oxygen for measurement
Sensor poisoning Can be affected by certain contaminants Not subject to catalytic poisoning
Typical considerations Gas composition, oxygen availability and sensor condition Gas absorption characteristics and optical conditions

Neither technology is universally better. The appropriate choice depends on the target gas, operating environment, maintenance requirements and the design of the gas detection system.

Catalytic detection can be a practical solution for monitoring a range of combustible gases when the selected sensor is suitable for the application.

4. Why Use a Fixed Gas Transmitter in Industrial Applications?

Portable gas detectors are useful for personal monitoring, inspections and maintenance activities. However, they do not replace continuous monitoring in locations where combustible gas leaks may present an ongoing risk.

Fixed gas transmitters are installed at designated monitoring points and continuously measure gas concentrations.

Their main advantages include:

  • Continuous monitoring: Gas concentrations are measured without requiring an operator to carry a detector.

  • Integration with control systems: Measurement signals can be transmitted to PLCs, control panels and building management systems.

  • Remote monitoring: Operators can monitor gas conditions from a central control room.

  • Alarm functionality: Compatible configurations can provide relay outputs for external alarm or control equipment.

  • Industrial installation: Dedicated housings and protection ratings allow installation in demanding environments when the equipment is correctly selected.

The location of fixed detectors is particularly important. Installation points should be determined according to gas density, possible leak sources, ventilation conditions and the characteristics of the monitored process.

5. GfG CC33: A Fixed Gas Transmitter for Combustible Gas Monitoring

The GfG CC33 is a fixed gas transmitter designed for monitoring combustible gases and vapours in industrial environments.

It uses catalytic combustion measurement technology and supports integration into industrial monitoring and control systems.

The CC33 is available in different configurations, allowing users to select the housing material, signal output and additional functions according to their installation requirements.

Key Technical Features

  • Measuring principle: Catalytic combustion

  • Measuring range: 0–100% LEL (sensor dependent)

  • Response time: t90 ≤ 9 seconds (sensor dependent)

  • Power supply: 12–30 V DC

  • Signal outputs: 4–20 mA or RS485 Modbus RTU, depending on configuration

  • Display: 2.2-inch graphic display

  • Housing materials: Die-cast aluminium or stainless steel

  • Protection rating: IP67 with appropriate thread sealing; IP54 without additional thread sealing

  • Expected sensor lifetime: Approximately 5 years, depending on operating conditions

  • Operating temperature: Dependent on the selected sensor and explosion protection configuration

The transmitter is designed for use in hazardous areas and has ATEX explosion protection certification for applicable configurations.

Flexible Communication Options

One of the important considerations when selecting a fixed gas transmitter is how measurement data will be transferred to the monitoring system.

The GfG CC33 offers two main communication options:

4–20 mA analogue output

The standard industrial 4–20 mA signal allows the transmitter to communicate with PLCs, controllers and other monitoring equipment.

This option is particularly suitable for installations using conventional analogue input modules.

RS485 Modbus RTU

The digital RS485 interface supports Modbus RTU communication, allowing measurement data to be integrated into compatible automation systems.

This can be useful in installations where several measurement devices communicate with a central controller.

The appropriate version should be selected according to the available system interfaces and project requirements.

Aluminium or Stainless Steel Housing?

The CC33 is available with two housing materials.

Aluminium housing is a practical option for many standard industrial installations.

Stainless steel housing can be considered where greater material resistance and specific environmental requirements make it appropriate.

Both versions are designed for industrial applications, with the final selection depending on installation conditions and project specifications.

6. What Should You Consider When Selecting a Fixed Gas Transmitter?

Choosing a gas transmitter requires more than simply identifying the gas to be measured. Several technical factors should be evaluated before purchasing equipment.

1. Identify the Target Gas

First, determine which combustible gas or vapour needs to be monitored.

Different gases have different flammability characteristics and sensor response properties. Make sure the selected sensor is suitable for the target gas and its required calibration.

2. Define the Measuring Range

Many fixed gas detectors use %LEL as their measurement unit.

A measuring range of 0–100% LEL is commonly used for combustible gas monitoring. However, the appropriate measurement and alarm settings should be established according to the application and applicable safety requirements.

3. Check the Communication Interface

Determine whether your control system requires:

  • 4–20 mA analogue output

  • RS485 Modbus RTU

  • Relay outputs for external alarm or control equipment

Compatibility with existing PLCs and monitoring equipment should be confirmed before ordering.

4. Consider the Installation Environment

Temperature, humidity, dust, moisture and potential exposure to aggressive substances can influence equipment selection and sensor performance.

Check the transmitter's protection rating and the permitted environmental conditions for the selected configuration.

5. Verify Explosion Protection Requirements

If the transmitter is intended for installation in a potentially explosive atmosphere, its certification and protection marking must match the hazardous area classification.

The installation must also comply with applicable ATEX requirements and the manufacturer's instructions.

6. Plan Maintenance and Calibration

Fixed gas detection systems require regular inspection, functional testing and calibration according to the manufacturer's recommendations and site safety procedures.

The availability of calibration accessories and replacement sensors should also be considered when selecting equipment.

7. Where Are Catalytic Gas Transmitters Used?

Catalytic gas detection technology is used in a variety of industrial applications where combustible gases and vapours may be present.

Typical application areas include:

  • Chemical and petrochemical facilities: Monitoring combustible gases in process areas and storage installations.

  • Energy production: Monitoring areas where fuel gases are handled.

  • Industrial manufacturing: Detecting potential gas leaks around production equipment and machinery.

  • Gas storage facilities: Monitoring locations where combustible gases are stored or distributed.

  • Boiler rooms and heating installations: Monitoring areas where fuel gas leaks could create hazardous conditions.

  • Industrial ventilation systems: Providing gas measurement information for compatible monitoring and control systems.

The exact detector type, sensor position and alarm strategy should always be determined through an application-specific risk assessment.

8. Frequently Asked Questions About Catalytic Gas Detection

What gases can a catalytic gas detector measure?

Catalytic sensors can detect various combustible gases and vapours, including methane, propane, butane and hydrogen. The actual detection capability depends on the selected sensor and its calibration.

What is the difference between %LEL and %vol?

%LEL expresses gas concentration as a proportion of its Lower Explosive Limit, whereas %vol represents the actual volume concentration of gas in the air. These are different measurement units and should not be used interchangeably.

Does a catalytic gas sensor require oxygen?

Yes. Catalytic combustion sensors require oxygen for the oxidation reaction. Environments with insufficient oxygen may affect measurement performance.

What is the difference between a catalytic and an infrared gas detector?

Catalytic detectors measure the heat generated during catalytic oxidation. Infrared detectors measure the absorption of infrared radiation by gas molecules. The appropriate technology depends on the target gas and application conditions.

Can the GfG CC33 be connected to a PLC?

Yes. Depending on the selected configuration, the CC33 supports either a 4–20 mA analogue output or RS485 Modbus RTU communication. Both can be integrated with compatible industrial control systems.

Does the GfG CC33 include a gas sensor?

The CC33 transmitter configurations offered by ShopTransmitter are supplied without a gas sensor. The appropriate sensor must be selected and ordered separately according to the gas being monitored.

Is the GfG CC33 suitable for hazardous areas?

The CC33 has ATEX-certified configurations for use in specified hazardous areas. The exact certification marking, temperature limits and installation conditions must be checked against the selected version.

Need help choosing?

If you're not sure which transmitter and sensor combination fits your application, send us the gas, the location and your control system details, and we'll help you narrow it down. Browse the GfG fixed gas detection range at ShopTransmitter.